Low-pressure SCR Valve
- Temperature
- 20–420°C / 20–500°C
- Size
- 200A–3200A
- Actuation
- Pneumatic
R&D
Flow analysis compares pressure distribution and local velocity through a valve. At the same nominal size, pressure loss varies with opening, flow rate and fluid density. Meaningful comparisons require geometry and inlet/outlet conditions representative of the installation.
PRODUCT DATA


R&D
CFD examines velocity and pressure distribution at different valve openings. It helps assess pressure loss and local flow patterns.
Flow rate, fluid properties, valve opening, pressure loss and boundary conditions